24-551

Required side setbacks for tall buildings in low bulk districts

R1 R2 R3 R4 R5

In the districts indicated, except R5D Districts, no community facility portion of any building that is more than 35 feet or more than three stories above the level of a side yard, whichever is lower, shall be nearer to a side lot line bounding such yard than a distance equal to one-half the height above yard level of such portion of the building.

The following are permitted to project into any open area required under the provisions of this Section:

(a)        parapet walls, not more than four feet high; and

(b)        chimneys or flues, with a total width not exceeding 10 percent of the width of the building's walls facing such open area.

Zoning Resolutions 24-551.0

SIDE SETBACK REQUIREMENT